Arrangement of tower sensors. The names (sonic 1,2,3 and Tg,1,2,3) refer to the raw data files which correspond to the data available in the data base. Location at tower indicates in which direction the sensors were mounted as seen from the tower, the uncertainty here is about 10-20deg. Time when measurement commenced are the times from which on all sensors were active. CSAT-3 measurements resulting in v>50m/s should be discarded. (S.Els 0704.2008) T2-Armazones 28m tower Altitude CSAT-3 Location CSAT3 Temperature Location Time of commence at tower structure probe at tower of measurements 2m AWS -- -- Tg -- 2006-09-15 18UT 11m Sonic 3 N(NW) N T3 NE 2006-09-15 18UT 20m Sonic 2 N(NW) N T2 NE " 28m Sonic 1 N(NW) N T1 NE " Comments: - Malfunction of temperature probe T1(28m) between 20060929-20061022. Temperature readings during this periods are T1=20C and should be discarded. T3-Tolonchar 30m tower Altitude CSAT-3 Location CSAT-3 Temperature Location Time of commence at tower structure probe at tower of measurements 2m AWS -- -- Tg -- 2007-03-09 18UT 11m Sonic 1 N(NW) N T1 NE 2007-03-09 18UT 20m Sonic 2 N(NW) N T2 NE " 30m Sonic 3 N(NW) N T3 NE " Comments: - The 2m temperature probe (Tg) reads sporadically, but often, Tg=10C. Therefore, Tg=10C should be discarded.